Section 11 Multi-Function Timer Pulse Unit 2
Page 630 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Reset-Synchronized PWM Mode
Figure 11.126 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in reset-synchronized PWM mode after re-setting.
1
RESET
2
TMDR
(PWM1)
3
TOER
(1)
5
PFC
(MTU2)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(normal)
12
TIOR
(0 init
0 out)
13
TIOR
(
disabled
)
14
TOER
(0)
15
TOCR
16
TMDR
(RPWM)
17
TOER
(1)
18
PFC
(MTU2)
19
TSTR
(1)
MTU2
module
output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
Not initialized (TIOC3B)
Not initialized (TIOC3D)
High-Z
High-Z
High-Z
Figure 11.126 Error Occurrence in PWM Mode 1,
Recovery in Reset-Synchronized PWM Mode
1 to 14 are the same as in figure 11.125.
15. Select the reset-synchronized PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronized PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set the multi-function timer pulse unit 2 output with the general I/O port.