Section 33 Power-Down Modes
Page 1786 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
33.2.8 Standby Control Register 8 (STBCR8)
STBCR8 is an 8-bit readable/writable register that controls the operation of each module.
Note: When writing to this register, see section 33.4, Usage Notes.
76543210
Bit:
Initial value:
R/W:
111111 1
R/W R R R R R R/W
1
R
-
MSTP
87
---
MSTP
80
--
Bit Bit Name
Initial
Value R/W Description
7 MSTP87 1 R/W Module Stop 87
When the MSTP87 bit is set to 1, the clock supply to
the motor control PWM timer is halted.
0: The motor control PWM timer runs.
1: Clock supply to the motor control PWM timer is
halted.
6 to 1 All 1 R Reserved
These bits are always read as 1. The write value
should always be 1.
0 MSTP80 1 R/W Module Stop 80
When the MSTP80 bit is set to 1, the clock supply to
the decompression unit is halted.
0: The decompression unit runs.
1: Clock supply to the decompression unit is halted.