Section 11 Multi-Function Timer Pulse Unit 2
Page 594 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
11.6.2 Interrupt Signal Timing
(1) TGF Flag Setting Timing in Case of Compare Match
Figure 11.92 shows the timing for setting of the TGF flag in TSR on compare match, and TGI
interrupt request signal timing.
TGR
TCNT
TCNT input
clock
N
N
N + 1
Compare
match signal
TGF flag
TGI interrupt
Pφ
Figure 11.92 TGI Interrupt Timing (Compare Match)