Section 21 IEBus
TM
Controller
R01UH0134EJ0400 Rev. 4.00 Page 1147 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
21.7 Interrupt Sources
Interrupt sources for this module include the following:
Transmit start (TXS)
Transmit normal completion (TXF)
Arbitration loss (TXEAL)
Transmit timing error (TXETTME)
Overflow of the maximum number of transmit bytes in one frame (TXERO)
Acknowledge bits (TXEACK)
Receive busy (RXBSY)
Receive start (RXS)
Receive normal completion (RXF)
Broadcast Receive Error (RXEDE)
Receive overrun flag (RXEOVE)
Receive timing error (RXERTME)
Overflow of the maximum number of receive bytes in one frame (RXEDLE)
Parity error (RXEPE)
Each source has bits corresponding to the IEBus transmit interrupt enable register (IEIET) and the
IEBus receive interrupt enable register (IEIER) and can enable/disable interrupts. Each source also
has status flags corresponding to the IEBus transmit status register (IETSR) and IEBus receive
status register (IERSR). Reading the status flags allows determination of the interrupt sources.