Section 25 NAND Flash Memory Controller
R01UH0134EJ0400 Rev. 4.00 Page 1309 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
Bit Bit Name
Initial
Value R/W Description
8 STERB 0 R/(W)* Status Error
Indicates the result of status read. This bit is set to 1 if
the specific bit in the bits STAT[7:0] in FLBSYCNT is
set to 1 in status read.
This bit is a flag. 1 cannot be written to this bit. Only 0
can be written to clear the flag.
0: Indicates that no status error occurs (the specific bit
in the bits STAT[7:0] in FLBSYCNT is 0.)
1: Indicates that a status error occurs
For details on the specific bit in STAT7 to STAT0 bits,
see section 25.4.7, Status Read.
7 BTOERB 0 R/(W)* R/B Timeout Error
This bit is set to 1 if an R/B timeout error occurs (the
bits RBTIMCNT[19:0] in FLBSYCNT are decremented
to 0).
This bit is a flag. 1 cannot be written to this bit. Only 0
can be written to clear the flag.
0: Indicates that no R/B timeout error occurs
1: Indicates that an R/B timeout error occurs
6 TRREQF1 0 R/(W)* FLECFIFO Transfer Request Flag
Indicates that a transfer request is issued from
FLECFIFO.
This bit is a flag. 1 cannot be written to this bit. Only 0
can be written to clear the flag.
0: Indicates that no transfer request is issued from
FLECFIFO
1: Indicates that a transfer request is issued from
FLECFIFO