Section 11 Multi-Function Timer Pulse Unit 2
Page 620 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
(2) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in PWM Mode 1
Figure 11.116 shows an explanatory diagram of the case where an error occurs in normal mode
and operation is restarted in PWM mode 1 after re-setting.
1
RESET
2
TMDR
(normal)
3
TOER
(1)
5
PFC
(MTU2)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PWM1)
12
TIOR
(1 init
0 out)
13
PFC
(MTU2)
14
TSTR
(1)
MTU2 module output
TIOC*A
TIOC*B
Port output
PEn
PEn
Not initialized (TIOC*B)
n = 0 to 15
High-Z
High-Z
Figure 11.116 Error Occurrence in Normal Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 11.115.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, and then switch to PWM mode 1.)
13. Set the multi-function timer pulse unit 2 output with the general I/O port.
14. Operation is restarted by TSTR.