Section 28 Sampling Rate Converter
R01UH0134EJ0400 Rev. 4.00 Page 1663 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
28.4 Interrupts
This module has five interrupt sources: input data FIFO empty (IDEI), output data FIFO full
(ODFI), output data FIFO overwrite (OVF), output data FIFO underflow (UDF), and conversion
end (CEF). Table 28.11 summarizes the interrupts.
Table 28.11 Interrupt Requests and Generation Conditions
Interrupt Request Abbreviation Interrupt Condition
Direct Memory
Access Controller
Activation
Input data FIFO empty IDEI IINT = 1, IEN = 1, and
SRCEN = 1
Possible
Output data FIFO full ODFI OINT = 1, OEN = 1, and
SRCEN = 1
Possible
Output data FIFO overwrite OVF OVF = 1, OVEN = 1, and
SRCEN = 1
Not possible
Output data FIFO underflow UDF UDF = 1, UDEN = 1, and
SRCEN = 1
Not possible
Conversion end CEF CEF = 1, CEEN = 1, and
SRCEN = 1
Not possible
When the interrupt condition is satisfied, the CPU executes the interrupt exception handling
routine. The interrupt source flags should be cleared in the routine.
The IDEI and ODFI interrupts can activate the direct memory access controller when the direct
memory access controller is set to allow this. If the direct memory access controller is activated,
the interrupts from this module are not sent to the CPU. When the direct memory access controller
has written data to SRCID resulting in the number of data units in the input data FIFO exceeding
that of the specified triggering number, the IINT bit is cleared to 0. Similarly, when the direct
memory access controller has read data from SRCOD resulting in the number of data units in the
output data FIFO being less than the specified triggering number, the OINT bit is cleared to 0.