Mitsubishi Electronics FX-PCS-DU/WIN-E Model Vehicle User Manual


 
FX Series Programmable Controllers
Preparation for Drawing and Basic Options 5
5-18
5.4 Let’s turn on output using touch key switch
In some DU units, touch keys (switches) can be created at arbitrary size in arbitrary positions. In other DU
units (including the F940GOT), mechanical keys (such as ten-keys) are provided.
This paragraph describes the procedure to set a touch key which turns on the output Y0 of the PLC when
pressed.
Example of created screen
Start point (X: 80, Y: 32)
Touch Key Label: Y0 on/off
Key Type: Single frame (shaded)
Function: Switch
DU Output = Y0
Operation: Momentary
Operating procedure (Display the screen window in advance while referring to Paragraph 5.2.)
1) Left-click "Object" on the tool bar.
Point and left-click "Touch Key".
2) Put the mouse cursor at a desired start point on
the screen window, and left-click it.
The coordinates of the mouse cursor are displayed
as "X:
∗∗
Y:
∗∗
" at the lower right corner of the DU/
WIN-E software window.
(After creating a touch key, you can move it or
change its size using the Touch Key dialog box or
the mouse.)
(To next page)