Mitsubishi Electronics FX-PCS-DU/WIN-E Model Vehicle User Manual


 
FX Series Programmable Controllers Related Information 9
9-30
Up to 200 screens can be created, and the total data size of all the screens should be 30 KB or less. (For the
data size of each object, refer to the table on the left.)
Table 9.44:
Item Description
Total screen data size
30 KB (user screens, external characters, etc.)
Number of displayable screens
User screen: 200 screens maximum (screen Nos. 0 to 199)
System screen: 9 screens (screen Nos. 501 to 509)
Data size per screen
1,000 bytes maximum
Table 9.45:
Object name Data size per object Allowable number of objects per screen
Text
14 to 30 bytes 70
Ascii
16 bytes 2
Number
24 bytes
8 in all. However, up to 3 library texts.
Bar Graph
24 bytes
Library Text
24 bytes
Indicator
16 bytes
16 in all. However, up to 2 text indication.
Text indicator
16 bytes
Line
16 bytes 60
Circle
16 bytes 60
Box
16 bytes 60
Date
16 bytes
1 for each (when RTC cassette is used)
Time
16 bytes
Switch
8 bytes
6 in all. 1 change screen can be registered as common
setting for all screens.
Change screen
8 bytes
Text Library
8 to 28 bytes 100
FX-25DU-E
30 KB (all screens)
Number of objects x Data size
+ 256 bytes (fixed)
+ 4 KB (fixed for external characters)
+ Alarm messages
+ Text library
1,000 bytes
Data size of one screen
Variable depending on the number of objects registered