FX Series Programmable Controllers Object Function Description 8
8-91
5 ) Constant
Enter a numeric (integer) to be added (Increment) to or subtracted (Decrement) from the word device
specified in 2) Word Device.
The allowable constant range is as follows for both the "Increment" and "Decrement" objects.
3) Data Size = 16 bits: 0 to +32,767
32 bits: 0 to +2,147,483,647
6 ) Initialezed Value Conditions
Click to check the check box when using the word operation function of the touch keys.
While the data is added or subtracted in the condition set above, if the value of "2) Word Device"
becomes more or less than the value set in "Conditional Value", the value set in "Reset Value" is written
to "2) Word Device".