APPENDIX 5 Processing Times of the Motion CPU
The processing time of each signal and each instruction for positioning control in the
Multiple CPU system is shown below.
(1) Motion operation cycle [ms] (Default)
Q173HCPU Q172HCPU
Number of setting axes (SV22)
1 to 5 6 to 14 15 to 28 29 to 32
1 to 5 6 to 8
Number of setting axes (SV13) 1 to 3 4 to 10 11 to 20 21 to 32
1 to 3 4 to 8
Operation cycle [ms] 0.44 0.88 1.77 3.55 7.11 0.44 0.88 1.77
(2) CPU processing time [ms]
Q173HCPU Q172HCPU
Operation cycle 0.44 0.88 1.77 3.55 7.11 0.44 0.88 1.77
"WAIT ON/OFF"
+ Motion control
step
0.8 to 1.0 1.1 to 1.6 2.5 to 3.2 4.3 to 6.0 8.1 to 11.1 0.8 to 1.0 1.1 to 1.6 2.5 to 3.2
Servo program
start processing
time
(Note-1)
Only Motion
control step
1.0 to 1.6 1.8 to 2.3 3.0 to 3.9 4.8 to 6.6 9.4 to 11.5 1.0 to 1.6 1.8 to 2.3 3.0 to 3.9
Speed change response 0.9 to 1.2 1.2 to 2.0 2.8 to 3.6 4.5 to 5.9 8.5 to 11.0 0.9 to1.2 1.2 to 2.0 2.8 to 3.6
Torque limit value change
response
0.4
or less
0.8
or less
1.7
or less
3.5
or less
3.5
or less
0.4
or less
0.8
or less
1.7
or less
Simultaneous start processing
time
(Note-2)
0.9 to 1.6 1.7 to 2.5 3.5 to 4.2 5.0 to 6.5 8.6 to 12.0 0.9 to 1.6 1.7 to 2.5 3.5 to 4.2
Time from PLC ready flag
(M2000) ON to PCPU ready flag
(M9074) ON
39 to 433
(Note-1): FEED instruction varies greatly depending on the condition (whether other axes are operating or being stopped).
(Note-2): This processing time varies depending on the simultaneous start command. Use this time merely for reference.
(Note-3): If the servo amplifiers of 9 axes or more are connected to one SSCNET
system, it does not support an operation
cycle of 0.4[ms]. 0.8[ms] is used as the real operation cycle, even if 0.4[ms] is set in the system setting.