6 - 83
6 POSITIONING CONTROL
(3) Operation timing
Operation timing for fixed-pitch feed control using 2 axes linear interpolation is
shown below.
10000
V
t
PLC ready flag (M2000)
All axes servo ON command
(M2042)
All axes servo ON accept flag
(M2049)
Axis 2 servo ready (M2435)
Axis 3 servo ready (M2455)
Start command (PX000)
Servo program start
Axis 2 start accept flag
(M2002)
Axis 3 start accept flag
(M2003)
Servo program No.310
(4) Servo program
Servo program No.310 for fixed-pitch feed control using 2 axes linear
interpolation is shown below.
Fixed-pitch feed using 2 axes linear interpolation
<K 310>
FEED-2
Axis 2,
Axis 3,
Speed
500000
300000
10000
Axis used . . . . . . . . Axis 2, Axis 3
Travel value . . . . .
Axis 2 . . . 500000
Axis 3 . . . 300000
Positioning speed . . . . . . . . . . . . .
10000