Mitsubishi Electronics Q172HCPU Baby Accessories User Manual


 
6 - 48
6 POSITIONING CONTROL
(6) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
SET M2042
PX000*M2415*M2435
END
!PX000
Wait until PX000 turn off after circular interpolation
completion.
Turn on all axes servo ON command.
Wait until PX000, Axis 1 servo ready and Axis 2 servo
ready turn on.
Radius specified-circular interpolation control
Axis used . . . . . . . . . . . . . . . Axis 1, Axis 2
Positioning speed . . . . . . . . . . . . . . . . . . . . .
. . . . . . .
Axis 1 . . . 100000[PLS]
Axis 2 . . . . 50000[PLS]
End point address
Radius specified-circular
interpolation control
ABS
Axis 1, 100000PLS
Axis 2, 50000PLS
Speed 1000PLS/s
Radius 80000PLS
1000[PLS/s]
Radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radius specified-circular interpolation control
80000[PLS]
[F10]
[G10]
[G20]
[K41]
(Note): Example of the above Motion SFC program is started using the automatic start or PLC program.