6 -
176
6 POSITIONING CONTROL
[Cautions]
(1) If the forward JOG start command (M3202+20n) and reverse JOG start command
(M3203+20n) turn on simultaneously for a single axis, the forward JOG operation
is executed.
When a deceleration stop is made by the forward JOG start command OFF the
reverse JOG operation is not executed even if the reverse JOG start command is
ON. After that, when the reverse JOG start command turns off to on, the reverse
JOG operation is executed.
t
Forward JOG operation
V
OFF
ON
ON
OFF
Forward JOG
start command
Reverse JOG
start command
Reverse JOG
operation
Reverse JOG start
command ignored
(2) If the JOG operation command (M3202+20n/M3203+20n) turns on during
deceleration by the JOG operation command OFF, after deceleration stop,
JOG operation is not executed.
After that, the JOG operation is executed by the JOG operation command
OFF to ON.
t
JOG operation
V
ON
JOG operation
command
OFF