Mitsubishi Electronics Q172HCPU Baby Accessories User Manual


 
2 - 5
2 POSITIONING CONTROL BY THE MOTION CPU
Servo amplifier
Servomotor
Servo instruction
(Specification of the positioning control method)
Positioning data which must be set:
Axis used, positioning address and positioning
speed, etc.
Positioning data to be set if required:
Dwell time, M-code, etc.
<K 100>
ABS-1
Axis
Speed
Dwell time
M-code
4,
80000
10000
-
-
System settings
Fixed parameters
Servo parameters
Parameters block
Home position return data
JOG operation data
Limit switch output data
Servo program . . . . .
Positioning control parameters . . . . .
Create and correct using a
peripheral device
(Note-1)
Create and correct using a
peripheral device
(Note-1)
System data such as axis allocations
Fixed data by the mechanical system, etc.
Data by the specifications of the connected
servo amplifier
Data required for the acceleration, deceleration
of the positioning control, etc.
Data required for the home position return
Data required for the JOG operation
ON/OFF pattern data required for the limit
switch output function
REMARK
(Note-1) : The following peripheral devices started by the SW6RN-GSV P can be
used.
• The personal computer by which WindowsNT
R
4.0/Windows
R
98/
Windows
R
2000/Windows
R
XP works. (IBM PC/AT compatible)
WindowsNT
R
, Windows
R
are either registered trademarks or trademarks of
Microsoft Corporation in the United States and/or other countries.