Mitsubishi Electronics Q172HCPU Baby Accessories User Manual


 
APP - 51
A
PPENDICES
APPENDIX 4 Setting Range for Indirect Setting Devices
Positioning address, command speed or M-code, etc. (excluding the axis No.) set in
the servo program can be set indirectly by the word.
(1) Device range
The number of device words and device range at indirect setting are shown
below.
Item
Number of
device words
Device setting range Remarks
Address (travel value) 2
Command speed 2
Dwell time 1 Device Range
M-code 1 D 800 to 8191
Torque limit value 1 W 0000 to 1FFF
Common
Parameter block No. 1 # 0000 to 7999
Auxiliary point 2
Radius 2
Central point 2
Arc
Pitch 1
Control unit 1
Speed limit value 2
Acceleration time 1
Deceleration time 1
Rapid stop deceleration time 1
Torque limit value 1
STOP input deceleration processing
1
Circular interpolation error allowance range 2
Parameter block
S-curve ratio 1
Program No. 1 Simultaneous start
Command speed (Constant speed) 2
FIN acceleration/deceleration 1
Fixed position stop
acceleration/deceleration time
1
Repetition condition (Number of repetitions) 1
Repetition condition (ON/OFF)
Cancel
Device Range
Skip X 0000 to 1FFF
WAIT ON/OFF Y 0000 to 1FFF
Fixed position stop M/L 0 to 8191
Special relay 9000 to 9255
B 0000 to 1FFF
F 0 to 2047
Others
Bit
(Note): Synchronous encoder axis area cannot be set.
POINT
Be sure to set even-numbered devices for 2-word setting items.
Be sure to set as 32-bit integer type when the data is set in these devices using the
Motion SFC programs. (Example : #0L, D0L)