Mitsubishi Electronics Q172HCPU Baby Accessories User Manual


 
APP - 18
A
PPENDICES
(2) Positioning control errors (1100 to 1199)
These errors are detected at the positioning control.
The error codes, causes, processing and corrective actions are shown in Table
1.9.
Table 1.9 Positioning control error (1100 to 1199) list
Control mode
Error
code
Positioning
Fixed-pitch feed
Speed
Speed/position switching
Speed switching
Constant-speed
JOG
Manual pulse generator
Home position return
Position follow-up control
OSC
Speed control with
fixed
p
osition sto
p
Error cause
Error
processing
Corrective action
1101
• The external signal FLS
(upper limit LS) turned off
during the forward direction
(address increase direction).
• Travel in the reverse direction
by the JOG operation, etc. and
set within the external limit
range.
1102
• The external signal RLS
(lower limit LS) turned off
during the reverse direction
(address decrease
direction).
• Travel in the forward direction
by the JOG operation, etc. and
set within the external limit
range.
1103
• The external STOP signal
(stop signal) turned on
during home position return
of proximity dog type.
Decelera-
tion stop by
"Stop
processing
on STOP
input" of the
parameter
block.
• Perform the home position
return after move to the
proximity dog ON by the JOG
operation, etc. at the home
position return of the proximity
dog type.
1104
• The servo error detection
signal turned on during
positioning control.
Immediate
stop without
decelera-
ting.
• Start after disposal at the servo
error.
1105
• The power supply of the
servo amplifier turned off
during positioning control.
(Servo not installed status
detection, cable fault, etc.)
• Home position return did not
complete normally without
stop within the in-position
range of home position at
the home position return.
Turn the
servo
READY
(M2415+
20n) off.
• Turn on the power supply of the
servo amplifier.
• Check the connecting cable to
the servo amplifier.
• Make the gain adjustment.
• Q172EX or encoder
hardware error.
• Disconnected encoder cable.
Immediate
input stop
• Check (replace) the Q172EX or
encoder.
• Check the encoder cable.
1151
• A synchronous encoder set
in the system setting differs
from a synchronous
encoder actually connected.
• Q170ENC is connected to
Q172EX/Q172EX-S1.
Input from
synchro-
nous
encoder
does not
accept.
• Set a synchronous encoder
actually connected in the
system setting.
• Use Q172EX/Q172EX-S1 to
connect Q170ENC.