Leica 1000Z01 Model Vehicle User Manual


 
88 TPS-System 1000 Programs-2.3.1en © Leica
IV
EL
AH
OH
BS
SM
AS
FS
FREST\ CONFIGURATION
14:03
Log FlName : FREE_STA.LOG
MC
Hz Ori Acc : 0°00'32"
Ht Acc TP : 0.0250 m
Posn Acc TP : 0.0250 m
Two Faces : NO
User Displ. : NO
Log File : OFF
INFO DFLT EDIT
F1
F2 F3
F4
F5 F6
HELP I<>II
The "Configuration Editor" sets parameters for further
program operations:
Hz Ori Acc : Limit for the standard deviation of the
orientation. The orientation is
regarded as "error free", if the
computed standard deviation of the
orientation is within twice the entered
value.
Ht Acc TP : Height accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The height is regarded as "error free",
if the computed standard deviation is
within twice the entered value.
Configuration
Configuration Editor
Start the "Configuration Editor" from the "STATION
DATA" dialog.