© Leica TPS-System 1000 Programs-2.3.1en 45
IV
EL
AH
OH
RE
Configuration
Configuration Editor
RESEC\ CONFIGURATION
14:03
INFO DFLT EDIT
Log FlName : RESECT.LOG
MC
F1
F2 F3
F4
F5 F6
HELP
Hz Ori Acc : 0°00'32"
Ht Acc TP : 0.025 m
Posn Acc TP : 0.025 m
Two Faces : NO
User Displ : NO
Log File : OFF
The "Configuration Editor" sets parameters for further
program operations:
Hz Ori Acc : Limit for the standard deviation of the
orientation. The orientation is
regarded as "error free", if the
computed standard deviation of the
orientation is within twice the entered
value.
Ht Acc TP : Height accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The height is regarded as "error free",
if the computed standard deviation is
within twice the entered value.
Start the "Configuration Editor" from the "STATION
DATA" dialog.