© Leica TPS-System 1000 Programs-2.3.1en 143
IV
EL
AH
OH
BS
SM
AS
FS
BL
HB
KM
FB
SA
Configuration
Configuration Editor
Start the "Configuration Editor" from the "SETS
MENU" dialog.
F1
F2 F3
F4
F5 F6
HELP
SETS\ CONFIGURATION
14:03
MC
INFO DFLT LIST
Meas Method : <>
User Displ : NO
Hz Tol. : 0°00'16"
V Angle Tol : 0°00'16"
Log File : OFF
Log FlName : SETS.LOG
The "Configuration Editor" sets parameters for further
program operations:
Meas Method : > <All targets have to be observed for
face II in opposite order to the
observations in face I.
> >All targets have to be observed in
face II using the same sequence as for
the observations in face I.
◊ Each target has to be observed in
face II immediately after its
measurement for face I has been
completed.
User Displ : Set to YES, the display defined in the
"MEAS" application will be used.
NO uses the "SETS OF ANGLES"
default display.