Leica 1000Z01 Model Vehicle User Manual


 
290 TPS-System 1000 Programs-2.3.1en © Leica
IV
EL
AH
OH
BS
SM
AS
FS
BL
HB
KM
FB
SA
PZ
LB
TB
CO
RP
Catch Offs : This value is where the pole is in
relation to where the existing ground
intersects the design slope of the
template.
Catch HgtD : This value is the vertical difference
from the ground shot to where the
existing ground catches the template.
Hinge Offs : This is the horizontal distance from
the prism to where the template begins
the slope (hinges).
Hinge HgtD : The vertical difference between the
ground shot and the hinge point.
CL Offset : The horizontal distance from the
ground shot to the centerline.
CL HgtDiff : The vertical distance from the ground
shot to the centerline.
The following illustration represents the various
components of the REFPT option.
Centerline
CL Offset
Hinge Offs
Catch Offs
RPLUS13
CL HgtDiff
Hinge HgtD
Catch HgtD