Leica 1000Z01 Model Vehicle User Manual


 
© Leica TPS-System 1000 Programs-2.3.1en 113
IV
EL
AH
OH
BS
SM
AS
FS
BL
HB
HP
Meas. Tol : Limit for the difference between the
given and measured spacing of the
reflectors. If the tolerance value is
exceeded, the program will issue a
warning.
In case of measurements with 3 prism
the values are also used as limit for
the max. deviation of the 3
measurements.
Add. const. : Input of prism constant for the prisms
of the pole. The prism constant set in
the system is disregarded.
No. of Refl. : Number of the reflectors on the rod
you are using. Move the input cursor
to this line, then toggle to either 2 or 3.
Auto pos. : On the program will automatically
point the telescope of a motorized
theodolite at the third reflector once
the first two reflectors have been
measured. The exact pointing must be
made manually.
Rod Length : Total length of hidden-point rod.
Space R1-R2 : Spacing between the centers of
reflector R1 and reflector R2.
Space R1-R3 : Spacing between the centers of
reflector R1 and reflector R3. Enter
only for rods with three reflectors.
Reflector 3 must be situated between
reflector 1 and 2.
Displays date and version of the running application.
Set values to default. Default values are displayed on
page 112.
Accept the current configuration and proceed to
"MEASURE ROD"
Note that all parameters for the rod you are using must
be defined before you can proceed. If any of the
parameters have not been defined, the program will
issue an error message to this effect. Press OK to clear
the message, then make any necessary settings in the
"CONFIGURATION".