7 - 7
7 AUXILIARY AND APPLIED FUNCTIONS
Setting for the torque limit value with the constant-speed control (CPSTART 1)
(1) Servo program
Setting items of the
parameter block
Parameter block 3 (P.B.3)
setting at the start
Torque setting from
the pass point
(2) Parameter block
Torque limit value
setting
(3) Operation description
0
300[%]
40000
P1
V
1
Constant-speed control
Torque limit to
the servo amplifier
P2
Torque control with
torque limit value
(300[%]) of the parameter
block 3 (P.B.3).
Torque control with
torque limit value
(50[%]) of the servo
program.
50[%]
Parameter block or torque limit
value specified with the servo
program at the start.
60000
Exam
p
le