1 - 5
1 OVERVIEW
1.2.2 Differences between Q173HCPU/Q172HCPU and Q173CPU(N)/Q172CPU(N)
(1) Differences between Q173HCPU/Q172HCPU and
Q173CPU(N)/Q172CPU(N)
Item Q173HCPU Q172HCPU Q173CPU(N) Q172CPU(N)
Number of control axes Up to 32 axes Up to 8 axes Up to 32 axes Up to 8 axes
SV13
0.44ms/ 1 to 3 axes
0.88ms/ 4 to 10 axes
1.77ms/11 to 20 axes
3.55ms/21 to 32 axes
0.44ms/ 1 to 3 axes
0.88ms/ 4 to 8 axes
0.88ms/ 1 to 8 axes
1.77ms/ 9 to 16 axes
3.55ms/17 to 32 axes
0.88ms/ 1 to 8 axes
Operation cycle
(Default)
(It can be set up by
parameters.)
SV22
0.88ms/ 1 to 5 axes
1.77ms/ 6 to 14 axes
3.55ms/15 to 28 axes
7.11ms/29 to 32 axes
0.88ms/ 1 to 5 axes
1.77ms/ 6 to 8 axes
0.88ms/ 1 to 4 axes
1.77ms/ 5 to 12 axes
3.55ms/13 to 24 axes
7.11ms/25 to 32 axes
0.88ms/ 1 to 4 axes
1.77ms/ 5 to 8 axes
Motion SFC program capacity
Code total : 543 kbyte
Text total : 484 kbyte
Code total : 287 kbyte
Text total : 224 kbyte
Peripheral devices I/F USB/SSCNET USB/RS-232/SSCNET
Servo amplifier I/F
SSCNET
(Optical
communication)
Q173HCPU : 2 systems
Q172HCPU : 1 system
SSCNET
Q173CPU(N) : 4 systems
(Note-1)
Q172CPU(N) : 1 system
Fixed position stop function with
speed control
—
Phase compensation function
—
Indirect setting of home position
return data
Indirect setting with word devices (D, W, #) of
Motion CPU.
Only direct setting by programming software.
Expansion of speed setting range in
the unit [degree]
• When the speed control 10
multiplier setting
for degree axis is valid ;
0.01 to 21474836.47[degree/min]
• When the speed control 10
multiplier setting
for degree axis is invalid ;
0.001 to 2147483.647[degree/min]
0.001 to 2147483.647[degree/min] fixed
Fetch of external signal input Q172LX/General input of servo amplifier
(Note-2)
Q172LX
Optional data monitor function 3 points/axis (Specified device D, W, #)
—
Minor error [303], [304]
When the speed change is executed after
positioning automatic decerelation start or during
decerelation by the JOG start command signal
(M3202+20n, M3203+20n) OFF, since the
speed change request is ignored, a minor error
[303], [304] will not occur.
When the speed change is executed after
positioning automatic decerelation start or during
decerelation by the JOG start command signal
(M3202+20n, M3203+20n) OFF, a minor error
[303], [304] will occur.
Processing with power supply OFF
of servo amplifier
Servo OFF is executed for all servo amplifier
connected behind servo amplifier with which the
control power supply was turned OFF.
Servo OFF is executed for only servo amplifier
with which the control power supply was turned
OFF.
Back-up battery for internal memory
Internal rechargeable battery
(Set the external battery (Q6BAT) if continuous
power off time is longer for 1 month or more.)
(Note-3)
Internal rechargeable battery
(Set the external battery (A6BAT/MR-BAT) if
continuous power off time is longer for 1 month or
more.)
(Note-4)
(Note-1) : Use the Dividing unit (Q173DV) or dividing cable (Q173J2B CBL M/Q173HB CBL M).
(Note-2) : When selecting the each servo amplifier general input, the speed/position switching control cannot be executed. And, the external
stop input cannot be used.
(Note-3) : When adding the external battery (Q6BAT), use the Q170HBATC.
(Note-4) : When adding the external battery (A6BAT/MR-BAT), use the Q173DV (Q173HCPU use) or Q170BAT (Q172HCPU use).