5. Base Specifications Parameters
60
# Items Details
Setting range (unit)
1901
(PR)
station addr Set up a station address number (the NC is the n-th
slave station).
1 to 7
1902
(PR)
Din size Set up the size of the data to be transferred from the
PC to the NC (from the master station to the slave
station) in bytes (8 points).
0 to 32
(bytes (8 bits))
1903
(PR)
Dout size Set up the size of the data to be transferred from the
NC to the PC (from the slave station to the master
station) in bytes (8 points).
0 to 32
(bytes (8 bits))
1904
(PR)
data length Set up the data length of a character. 0 to 2 : 7 bits
3 : 8 bits
1905
(PR)
baud rate Set up a data transfer rate. The transfer rate differs
according to operation clock rates.
Clock: 6/10 MHz
0: 38400 / 57600
1: 19200 / 28800
2: 9600 / 14400
3: 4800 / 7200
4: 2400 / 3600
5: 1200 / 1800
6: 600 / 900
(bps)
1906
(PR)
stop bit Set up the stop bit length. 0 and 1: 1 bit
2 and 3: 2 bits
1907
(PR)
parity check Select whether to make a parity check. 0: Invalid
1: Valid
1908
(PR)
even parity Select the odd or even parity bit. If no parity check is
specified, this parameter is ignored.
0: Odd parity
1: Even parity
1909
(PR)
Tout (ini) (ini) specifies a time-out from when the connection
check sequence finishes to when the first usual
sequence (input) finishes.
0 to 999
(0.1 s)
1910
(PR)
(run) (run) specifies a time-out from when the NC (slave
station) outputs usual sequence data to when the next
usual sequence data is input.
If the time-out is exceeded, an emergency stop occurs
and the system waits for the preparation sequence to
start.
If the set value is 0, no time-out occurs or no communi-
cation stop can be detected.
1911
(PR)
clock select Select an operation cycle. 0: 6 MHz
1: 10 MHz
1926
(PR)
IP address Set NC's IP address.
1927
(PR)
Subnet mask Set sub-net mask.
1928
(PR)
Gateway address Designate gateway IP address.
Set these according to
connection environ-
ment's network
regulations.