5. Base Specifications Parameters
35
# Items Details
Setting range (unit)
1155
DOOR_m
Signal input
device 1 for
door interlock
II
Set up a fixed device number (X??) for door interlock II
signal input.
A device number from X001 to X3FF can be set up.
Device number 000 is invalid. Set up device number
100 when using no fixed device number for door
interlock II signal input.
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Related parameter: "#1154 pdoor" Door interlock II
(for each part system)
000 to 3FF
(hexadecimal)
1156
DOOR_s
Device
number 2 for
door interlock
II signal input
Set up a fixed device number (X??) for door interlock II
signal input. (Set up the same value as that of #1155.)
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
Related parameter: "#1154 pdoor" Door interlock II
(for each part system)
000 to 3FF
(hexadecimal)
1157 F0atrn F0 automatic
running
Not used.
1158 F0atno F0 automatic
running
program
Not used.
1166 fixpro Fixed cycle
editing
Select whether to use the edit‚ program list‚ and data
input/output functions for the fixed cycle or general
program.
0: Editing‚ etc.‚ of general program will be possible.
1: Editing‚ etc.‚ of fixed cycle will be possible.
0/1
1167 e2rom Not used.
1168 test Simulation
test
Specify the test mode for the control unit.
The test mode does not use reference point return‚ and
tests with a hypothetical reference point return
completed state. This is limited to test operation of the
control unit itself‚ and must not be used when
connected to the machine.
0: Normal
operation mode
1: Test mode