Mitsubishi Electronics C6 Crib Toy User Manual


 
8. Spindle Parameters
8.4 MDS-C1-SPM
246
No. Items Details
Setting
range
Standard
setting
3276 SP076 FONS Machine
resonance
suppression
filter
operation
speed
When the vibration increases in motor stop
(ex. in orientation stop) when the machine
vibration suppression filter is operated by
SP070, operate the machine vibration
suppression filter at a speed of this parameter
or more.
When set to "0", this is validated for all speeds.
0 to 32767
(r/min)
0
3277
(PR)
SP077 TDSL Fixed control
constant
Set by Mitsubishi.
Set "14" unless designated in particular.
14
3278
(PR)
SP078 FPWM Fixed control
constant
Set by Mitsubishi.
Set "1" unless designated in particular.
1 1
3279
SP079 Use not possible. 0 0
3280 SP080 SWTD Fixed control
constant
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0
3281
to
3286
SP081
to
SP086
Use not possible. 0 0
3287
(PR)
SP087 DIQM Target value
of variable
torque limit
magnifica-
tion at
deceleration
Set the minimum value of variable torque limit
at deceleration.
0 to 150
(%)
75
3288
(PR)
SP088 DIQN Speed for
starting
change of
variable
torque limit
magnifica-
tion at
deceleration
Set the speed where the torque limit value at
deceleration starts to change.
SP088 SP017
100%
SP087
Torque limit
Speed
Inversely proportional
to speed
0 to 32767
(r/min)
3000
3289
to
3292
SP089
to
SP092
Use not possible. 0 0
3293
(PR)
SP093 ORE Tolerable
pulse check
error
Set this when detecting the pulse detector's
pulse mistakes.
(Valid only for full close control.)
0 to 32767 0
3294
(PR)
SP094 LMAV Load meter
output filter
Set the filter time constant of load meter
output.
When "0" is set, a filter time constant is set to
100ms.
0 to 32767
(2ms)
0
3295
(PR)
SP095 VFAV Fixed control
constant
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0