Mitsubishi Electronics C6 Crib Toy User Manual


 
8. Spindle Parameters
8.2 MDS-B-SPJ2
188
No. Items Details
Setting
range
Standard
setting
3248
(PR)
SP048 SUT Speed reach
range
Set the speed deviation rate with respect to
the commanded speed for output of the
speed reach signal.
0 to 100
(%)
15
3249 SP049 TLM2 Torque limit 2 Set the torque limit rate for the torque limit
signal 010.
1 to 120
(%)
20
3250 SP050 TLM3 Torque limit 3 Set the torque limit rate for the torque limit
signal 011.
1 to 120
(%)
30
3251 SP051 TLM4 Torque limit 4 Set the torque limit rate for the torque limit
signal 100.
1 to 120
(%)
40
3252 SP052 TLM5 Torque limit 5 Set the torque limit rate for the torque limit
signal 101.
1 to 120
(%)
50
3253 SP053 TLM6 Torque limit 6 Set the torque limit rate for the torque limit
signal 110.
1 to 120
(%)
60
3254 SP054 TLM7 Torque limit 7 Set the torque limit rate for the torque limit
signal 111.
1 to 120
(%)
70
3255
(PR)
SP055 SETM Excessive
speed
deviation timer
Set the timer value until the excessive speed
deviation alarm is output.
The value of this parameter should be
longer than the acceleration/deceleration
time.
0 to 60 (s) 12
3256 SP056 PYVR Variable
excitation
(min value)
Set the minimum value of the variable
excitation rate.
Select a smaller value when gear noise is
too high. However, a larger value is effective
for impact response.
0 to 100
(%)
50
3257
(PR)
SP057 STOD Fixed control
constant
Set by Mitsubishi.
Set "0" unless designated in particular.
0 0
3258
to
3262
SP058
to
SP062
Not used. Set to "0". 0 0
3263
(PR)
SP063 OLT Overload alarm
detection time
Set the time constant for detection of the
motor overload alarm.
0 to 1000
(s)
60
3264
(PR)
SP064 OLL Overload alarm
detection level
Set the detection level of the motor overload
alarm.
0 to 120
(%)
110
3265
(PR)
SP065 VCGN1 Target value of
variable speed
loop
proportional
gain
Set the magnification of speed loop
proportional gain with respect to SP022
(VGNP1) at the maximum motor speed
defined in SP017 (TSP).
0 to 100
(%)
100
3266
(PR)
SP066 VCSN1 Change
starting speed
of variable
speed loop
proportional
gain
Set the speed for starting change of speed
loop proportional gain.
SP066 SP017
SP022
SP022×
(SP065/100)
Proportional gain
Speed
0 to 32767
(r/min)
0