Mitsubishi Electronics C6 Crib Toy User Manual


 
8. Spindle Parameters
8.4 MDS-C1-SPM
244
No. Items Details
Setting
range
Standard
setting
3256
SP056 Use not possible. 0 0
3257
(PR)
SP057 STOD
Constant
excessive
judgment
value
Set the value for judging when changing from
a constant to excessive speed command.
0 to 50
(r/min)
0
3258
(PR)
SP058 SDT2 2nd speed
detection
speed
Set the speed for turning the 2nd speed
detection ON.
(This is valid only when SP038: SFNC6-bit8
is set to "1".)
If the speed drops below this set speed, the
2nd speed detection will turn ON.
When the speed reaches this set speed
+15r/min or more, the 2nd speed detection
will turn OFF.
If SP034: SFNC2-bit1 is set to "1", this will be
the medium-speed and high-speed coil
changeover speed.
The speed detection reset width follows the
SP047 (speed detection reset width) setting.
0 to 32767
(r/min)
0
3259
(PR)
SP059 MKT Winding
changeover
base shut-off
timer
Set the base shut-off time for contactor
switching at winding changeover.
Note that the contactor may be damaged with
burning if the value of this parameter is too
small.
50 to
10000
(ms)
150
3260
(PR)
SP060 MKT2 Current limit
timer after
winding
changeover
Set the current limit time to be taken after
completion of contactor switching at winding
changeover.
0 to 10000
(ms)
500
3261
(PR)
SP061 MKIL Current limit
value after
winding
changeover
Set the current limit value during a period
defined in SP060 (MKT2) after completion of
contactor switching at winding changeover.
0 to 120
(%)
75
3262
SP062 Not used. Set to "0". 0 0
3263
(PR)
SP063 OLT Overload
alarm
detection time
Set the time constant for detection of the
motor overload alarm.
0 to 1000
(s)
60
3264
(PR)
SP064 OLL Overload
alarm
detection level
Set the detection level of the motor overload
alarm.
0 to 180
(%)
110
3265
(PR)
SP065 VCGN1 Target value
of variable
speed loop
proportional
gain
Set the magnification of speed loop
proportional gain with respect to SP022
(VGNP1) at the maximum motor speed
defined in SP017 (TSP).
0 to 100
(%)
100