5. Base Specifications Parameters
45
# Items Details
Setting range (unit)
(Continued from the previous page)
1: Accelerating time is obtained by G0tL+G0t1
(G1tL+G1t1).
When the acceleration/deceleration before G00
interpolation and the software
acceleration/deceleration are used one together, if
the same time is set to S-curve filter time (#1131
F1dcc) and the software acceleration/deceleration
2nd step time constant (#2005 G0t1), the G00
acceleration can be obtained equals as G28/G30.
G0tLG0t1
G0tL
G0t1
Speed
Acceleration
t
t
G0t1
1. Total accelerating time is obtained by
“G0tL+G0t1”.
2. The time for curve part is “G0t1”.
3. The time for linear part is obtained by
“G0tL-G0t1”.
(Note) This parameter is valid on the software Ver.C3
and later.
1220 aux04
(bit 0)
(For L
system
only)
Tool life
check timing
selection
Specify the life check standard applicable when the use
count is incremented in tool life management II.
0: Determines that the tool life is over when the
incremented use count exceeds the life count.
(Use count > life count)
1: Determines that the tool life is over when the
incremented use count has reached the life
count. (Use count life count)
0/1