8. Spindle Parameters
8.2 MDS-B-SPJ2
187
No. Items Details
Setting
range
Standard
setting
3241
(PR)
SP041 PTYP Power
supply type
When this unit is a signal connection axis with
power supply unit, set this parameter.
Set "0" for this parameter for the unit which is
not a signal connection axis.
Select a value from the following table
according to the regenerative resistance being
used.
(Note 1) This setting is used when using one
FCUA-RB75/2 and when using two in
parallel.
0000 to
FFFF
HEX
setting
0000
3242
(PR)
SP042
Not used. Set to “0”.
0 0
3243
(PR)
SP043
Not used. Set to “0”.
0 0
3244
(PR)
SP044 TRANS NC
communi-
cation
frequency
Set a frequency of data communication with
NC.
0 to 32767 Standard:
0
Special:
1028
3245
SP045
Not used. Set to “0”.
0 0
3246
(PR)
SP046 CSN2 Speed
command
dual
cushion
For an acceleration/deceleration time constant
defined in SP019 (CSN1) , this parameter is
used to provide smooth movement only at the
start of acceleration/deceleration.
As the value of this parameter is smaller, it
moves smoother but the
acceleration/deceleration time becomes
longer.
To make this parameter invalid, set "0".
0 to 1000 0
3247
(PR)
SP047 SDTR Speed
detection
reset value
Set the reset hysteresis width for a speed
detection set value defined in SP020 (SDTS).
0 to 1000
(r/min)
30
Setting
value
Regenerative
resistance type
Resistance
value ()
Capacity
(W)
0000
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
2A00
2B00
2C00
Not connected
FCUA-RB04
FCUA-RB075
FCUA-RB15
FCUA-RB22
FCUA-RB37
FCUA-RB55
FCUA-RB75/2
R–UNIT–1
R–UNIT–2
R–UNIT–3
R–UNIT–4
R–UNIT–5
200
100
60
40
25
20
30/15
30
15
15
10
10
60
80
120
155
185
340
340/680
700
700
2100
2100
3100