Patton electronic 1001MC Card Game User Manual


 
Model 1094 Configuration Slot page MIB variables description 82
Model 1001MC Operations Guide 5 • Model 1094ARC management
Line Status (lineStatus1094)
Displays the status of the line. There are three possible values that can be displayed:
startup(1)
dataMode(2)
testMode(3)
When the line status is dataMode(2), the units are linked-up and ready to send data.
Processor Mode (processorMode1094)
Displays the status of the processor running on the NetLink-HDSL. There are four values that are significant to
you:
normal(0)—When the processor is in normal(0) mode, the NetLink HDSL modem is monitoring itself
and sending the status information to the Model 1001MC
internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy down-
loading code to the internal DSP or setting the data pump.
negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and
the NetLink-HDSL is setting up the configuration parameters within the Model 1001MC
lineDown(3)
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the
NetLink-HDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set-
ting of the card.
Input Mode (mode1094)
The following settings are available:
onLine(0)
superVisoryMode1)
To make configuration changes to the NetLink-HDSL modems, you must first set this bit to
superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink
will appear on the web page next to the
Refresh Current Page hyperlink. Select the Modify Configuration
hyperlink. The
Model 1094A Configuration—Next Configuration page will appear (see section “Model 1094
Configuration—Next Configuration page MIB variables description” on page 84 for more information). After
making configuration changes to the NetLink-HDSL modems in the Model 1094A
Update Configuration
page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model
1001MC that the configuration has completed and will cause it to copy the new configuration into the
NetLink-HDSL configuration space. If this is not done, the NetLink-HDSL will not recognize the configura-
tion changes that were made.
Model 1094 Configuration Slot page Configuration Status table description
The Configuration Status table shows the configuration for the set of units. There are columns for the local and
remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:
At start up, the Model 1001MC will display a default configuration for the card and all fields will be high-
lighted in yellow, notifying you that the information has not been verified. During the negotiation phase,