Model 2707RC Configuration Slot page MIB variables description 181
Model 1001MC Operations Guide 8 • Model 2707RC management
Model 2707RC Configuration Slot page MIB variables description
This section describes the MIB variables that are available on the Model 2707RC Configuration Slot page.
Model 2707RC Configuration Slot (nmsSlotID)
Displays the address of the NetLink E1-G.703 NTU. The address is defined by the DIP-switch setting of S3
and S4 on the rack card.
Line Status (lineStatus)
Displays the status of the line. There are three possible values that can be displayed:
linedown(1)
dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
testMode(3)
Input Mode (mode2707RC)
The following settings are available:
onLine(0)
superVisoryMode(1)
To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1).
When the Input Mode is set to superVisoryMode(1), the Modify Configuration hyperlink will appear on the
web page next to the
Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model
2707RC Configuration—Configuration page will appear (see section “Model 2707RC Configuration—Con-
figuration page MIB variables description” on page 183 for more information). After making configuration
changes to the NetLink-E1 NTUs in the Model 2707RC
Configuration page, return to this page and place the
Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has com-
pleted and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is
not done, the NetLink-E1 NTU will not recognize the configuration changes that were made.
Model 2707RC Configuration Slot X page Configuration Status table description
The Configuration Status table shows the configuration for the 2707RC card. If a field is highlighted in yellow,
it signifies one of two possible conditions:
At start up, the Model 1001MC will display a default configuration for the card and all fields will be high-
lighted in yellow, notifying you that the information has not been verified. During the negotiation phase,
the NetLink-E1 NTU modem will update the configuration in the Model 1001MC with its last set of
stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disap-
pear, signifying that the information has been updated. After the local and remote units are linked, the units
will begin updating the remote information in the table, and Line Status set to datamode(2).
If a rack card is installed in the rack without a customer premise unit connected, the remote information
will be left as either none or highlighted in yellow, notifying you that the information has not been verified.
The following sections define the MIB variables that are shown in the Configuration Status table.