Model 2707RC Configuration Slot page MIB variables description 182
Model 1001MC Operations Guide 8 • Model 2707RC management
Configuration Status (configStatus2707RC)
Displays the configuration status of the rack card. The following status can be displayed:
Negotiating(0)—The 1001MC is receiving the rack card’s configuration for the first time
Static(1)—The 1001MC is showing the updated and correct configuration for the 2707RC
ImplementingChanges(2)—The 1001MC is updating configuration changes to the 2707RC.
Model Code (localModelCode/remoteModelCode)
These variables display the local and remote models codes for the units that were found in the specified address.
Line Format (lineFormat)
The following status variable can be displayed:
unframe-G703(0)—Sets the line format to G.703 unframed
Clock Mode (clockMode2707RC)
This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis-
played:
network-CLK(0)
internal-CLK(1)
external-CLK(2)
DTE rate (dteRate2707RC)
This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti-
vated channels.
Line Coding (lineCoding2707RC)
The following status variables can be displayed:
AMI line coding
HDB3 line coding.
Line Build Out (lineBuildOut)
This displays the selected line build out: either 75 ohm or 120 ohm.
FP Switches (frntSwitch)
This displays if the front panel toggle switches used for loopbacks and pattern generators are enabled or disabled.
H/W Test mode (testModeSetInd)
This displays any test mode invoked from the toggle switches and DTE test mode lines. This option will be
highlighted in blue if the unit is in test mode.
S/W Test mode (testModeSet2707RC)
This displays any test mode invoked through the NMS. See next configuration for information about invoking
test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.