System Level Information 238
Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Apply Test Mode
If you are going to be running in test mode, select one of the following test patterns from the pop-up menu,
then click the
Apply Test Mode button.
• off(0)
• five11(2)—511 is the pattern that is used when the pattern generator and detector are turned on
• five11er(3)—511 with errors is the pattern that is used when the pattern generator and detector are turned on
• lal(4)—Local loopback
• lalWith511(5)—Local loopback with pattern generator set to output 511 pattern
• lalWith511er(6)—Local loopback with pattern generator set to output 511 pattern with errors
• rdl(7)—Remote digital loopback
• rdlWith511(8)—Remote digital loopback with pattern generator set to output 511 pattern
• rdlWith511er(9)—Remote digital loopback with pattern generator set to output 511 pattern with errors
Rack Protection Mode
If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config-
ured, select protected(1) from the pop-up menu, then click the
Apply Protection button. For more information
about the system configuration feature, refer to section “System Config” on page 259.
Note Setting the Rack Protection Mode to normal(0) will enable the rack to
receive new configurations through the global configuration command.
Clear Rack X Alarms (clearAlarms)
Click on this button to clear alarms reported by the system for this rack.
Note The System Log will still display the errors after the Clear Rack X
Alarms button is clicked.