Patton electronic 1001MC Card Game User Manual


 
Model 1092 Configuration Slot page MIB variables description 61
Model 1001MC Operations Guide 4 • Model 1092ARC management
Model 1092 Configuration Slot page MIB variables description
This section describes the MIB variables that are available on the Model 1092 Configuration Slot page.
Model 1092A Model 1092 Configuration Slot (nmsSlotID)
Displays the address of the NetLink iDSL modem. The address is defined by the DIP-switch setting of S1 on
the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it
is connected to.
Line Status (lineStatusiDSL)
Displays the status of the line. There are three possible values that can be displayed:
startup(1)
dataMode(2)
testMode(3)
When the line status is dataMode(2), the units are linked-up and ready to send data.
Processor Mode (processorModeiDSL)
Displays the status of the processor running on the NetLink-iDSL. There are four values that are significant to you:
normal(0)—When the processor is in normal(0) mode, the NetLink iDSL modem is monitoring itself and
sending the status information to the Model 1001MC
internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy down-
loading code to the internal DSP or setting the data pump.
negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and
the NetLink-iDSL is setting up the configuration parameters within the Model 1001MC
lineDown(3)
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the
NetLink-iDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set-
ting of the card.
Input Mode (mode1092A)
The following settings are available:
onLine(0)
superVisoryMode1)
To make configuration changes to the NetLink-iDSL modems, you must first set this bit to
superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink
will appear on the web page next to the
Refresh Current Page hyperlink. Select the Modify Configuration
hyperlink. The
Model 1092A Configuration—Next Configuration page will appear (see section “Model 1092
Configuration—Next Configuration page MIB variables description” on page 63 for more information). After
making configuration changes to the NetLink-iDSL modems in the Model 1092A
Update Configuration page,
return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC
that the configuration has completed and will cause it to copy the new configuration into the NetLink-iDSL