Patton electronic 1001MC Card Game User Manual


 
Using the Download page to upgrade 1095RC software 111
Model 1001MC Operations Guide 6 • Model 1095RC management
useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within
this page.
Local Circuit ID (localCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Remote Circuit ID (remoteCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Alarm Information
Clear Slot Alarms (resetStatus)
Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Note The errors and warning will still be listed in the System Log.
Hardware Reset (resetStatus)
Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication)
This variable allows you to choose what type of indication will be made if a modem is removed from the man-
agement system. Three choices are available:
Error
Warning
None
Line Down Indication (lineDownIndication)
This variable allows you to choose what type of indication will be made if a modem reports a line down sce-
nario. Three choices are available:
Error
Warning
None
Note Line Down Indication must be set to error(2) line up and line down
SNMP trap messages to be sent.
Using the Download page to upgrade 1095RC software
Do the following to download new software into your NetLink modem:
1. Remove the card that you wish to upgrade from the rack chassis.
2. Make a note of the settings of DIP switches S2-6 and S2-7.
3. Set DIP switches S2-6 and S2-7 to the OFF position.