Patton electronic 1001MC Card Game User Manual


 
Creating and modifying global configuration templates 161
Model 1001MC Operations Guide 7 • Model 2701RC management
- qrss(0)—Quasi-random-signal-source
- five11(1)—The 511-bit length pseudo-random test pattern
- two047(2)—The 2047-bit length pseudo-random test pattern
Loop Timeout, determines the length of the in-band loop test. If the test is not of indefinite length, it will
automatically terminate the loop session.
- time-out-5min(0)—5 minutes
- time-out-10min(1)—10 minutes
- time-out-15min(2)—15 minutes
- time-out-30min(3)—30 minutes
- time-out-45min(4)—45 minutes
- time-out-60min(5)—60 minutes
- time-out-90min(6)—90 minutes
- time-out-120min(7)—120 minutes
- time-out-180min(8)—180 minutes
- no-time-out(9)—the loop runs indefinitely and must be turned off manually by the user.
Config Type
- Switch-config(0)—The 2701RC gets its configuration from the DIP switches on the card
- Software-config(1)—The 2701RC gets its configuration via the software configuration and not the DIP
switches.
Clock Mode, this selects the source of the clock used for the Transmit signal on the E1 channel. Please
note the difference from “Tx Clock Timing” described below.
- network-CLK(0)—derived from the received signal from the network
- internal-CLK(1)—driven by the internal oscillator in the 2701RC NTU
- external-CLK(2)—provided by DTE External Transmit Clock signal
Line Coding, the two commonly used types of line coding on E1 circuits
- code-HDB3(0)—most common
- code-AMI(1)—primarily in legacy equipment
CAS Multi Framing, refers to an E1 circuit which is using bit-oriented signaling in the multi-frame made
of 16 x 256-bit frames
- Disabled(0)
- Enabled(1)