Patton electronic 1001MC Card Game User Manual


 
Modem Information Rack X 242
Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Remote Model Code (remoteModelCode)
This column displays the model code of the NetLink modem at the far end of the link.
Protected
You can protect individual rack cards from being globally configured by setting the pop-up menu from nor-
mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur-
rent rack card, click on the
Submit button (located at the right side of the rack card’s row in the table) to save
the changes.
Note Setting the protection to normal(0) will enable the rack card to receive
new configurations through the global configuration command.
Note After submitting the protection setting, you must click on the Record
Current Conguration
button located on the HOME page to store
the configuration changes into memory (see “HOME” on page 228
for more information).
Local Circuit ID (localCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string
can be changed from the
Configure Cards page or from the Slot Configuration page (see section “Slot Config-
uration” on page 243 for more information). After you have set the local circuit ID, if you are finished making
changes to the current rack card, click on the
Submit button (located at the right side of the rack card’s row in
the table) to save the changes.
Note After submitting the local circuit ID information, you must click on
the
Record Current Conguration button located on the HOME
page to store the configuration changes into memory (see “HOME”
on page 228 for more information).
Remote Circuit ID (remoteCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string
can be changed from the
Configure Cards page or from the Slot Configuration page (see section “Slot Config-
uration” on page 243 for more information).
Submit button
Click the Submit button to input the changes to the management system. After clicking the Submit button, you
are required to select the
Record Current Conguration button on the Model 1001MC button on the Model
1001MC
HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Note After submitting the remote circuit ID information, you must click
on the
Record Current Conguration button located on the HOME
page to store the configuration changes into memory (see “HOME”
on page 228 for more information).