Model 3088RC Configuration Slot X page MIB variables description 201
Model 1001MC Operations Guide 9 • Model 3088RC management
Protected (disableGlobalConfig)
You can protect individual rack cards from being globally configured by setting the pop-up menu from nor-
mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur-
rent rack card, click on the
Submit button (located at the right side of the rack card’s row in the table) to save
the changes.
Note Setting the protection to normal(0) will enable the rack card to receive
new configurations through the global configuration command.
Note After submitting the protection setting, you must click on the Record
Current Conguration button located on the HOME page to store
the configuration changes into memory (see “HOME” on page 228
for more information).
Local Circuit ID (localCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string
can be changed within the
Configure Cards page or from the Slot Configuration page. After clicking the Sub-
mit Query button to input the string to the management system, you are required to select the Record Current
Conguration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the
information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string
can be changed from the
Configure Cards web page or from the Slot Configuration page.
Submit button
Click the Submit button to input the changes to the management system. After clicking the Submit button, you
are required to select the
Record Current Conguration button on the Model 1001MC button on the Model
1001MC
HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Note After submitting the remote circuit ID information, you must click
on the
Record Current Conguration button located on the HOME
page to store the configuration changes into memory (see “HOME”
on page 228 for more information).
Model 3088RC Configuration Slot X page MIB variables description
This section describes the MIB variables that are available on the Model 3088RC Configuration Slot X page.
(See figure 93 on page 193). Starting from the
HOME page, click on the following links: Home (menu) > Config-
ure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column).
Model 3088RC Configuration Slot (nmsSlotID)
Displays the address of the NetLink E1-G.SHDSL NTU. The address is defined by the DIP-switch setting of
S3 and S4 on the rack card.