Installing NetLink modem cards 19
Model 1001MC Operations Guide 2 • Hardware installation
3. Slide the front rack card into the front chassis slot 14 (see figure 6) until it meets the rear card receptacle.
When that happens, push the front card gently but firmly into the card-edge receptacle of the rear card, it
should click into place.
Figure 6. Rack chassis slot layout (front view)
4. Secure the front rack card using the captive fasteners.
Installing NetLink modem cards
This section contains hardware installation information that affects the following NetLink modems:
• Model 1092ARC (see section “Hardware setup for a Model 1092ARC”)
• Model 1094ARC (see section “Hardware setup for a Model 1094ARC” on page 22)
• Model 1095RC (see section “Hardware setup for a Model 1095RC” on page 24)
• Model 2701RC (see section “Hardware setup for a Model 2701RC” on page 26)
• Model 2707RC (see section “Hardware setup for a Model 2707RC” on page 28)
• Model 2710RC (see section “Hardware setup for a Model 2710RC” on page 29)
• Model 2715RC (see section “Hardware setup for a Model 2715RC” on page 29)
• Model 2088RC (see section “Hardware setup for a Model 3088RC” on page 29)
Hardware setup for a Model 1092ARC
The following must be done to configure your Model 1092ARC hardware for use with the Model 1001MC
network management station:
• Connect frame ground to signal ground (see section “Configuring frame ground”)
• Set the system address (see section “Setting the 1092ARC system address” on page 20)
When you are finished, install the Model 1092ARC front card and rear I/O card using the installation proce-
dures in the manual that came with the modem.
Configuring frame ground
The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system.
The Model 1092ARC rear I/O card must have frame ground (GND) connected to signal GND through a