Modem Information Rack X page MIB variables description 140
Model 1001MC Operations Guide 7 • Model 2701RC management
Figure 73. Web page navigation to Slot Configuration Page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables
description” on page 153.
Modem Information Rack X page MIB variables description
This section describes the MIB variables that are available on the Modem Information Rack X page. Starting
from the
HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack
number].
Slots Available (totalConfigSlots)
Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled)
Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies)
This is where you specify the number of power supplies installed in the rack (this value determines the addressing
range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will
inform the Model 1001MC that there should be 2 power supplies in the system.
Rack Protection Mode (rackXProtected)
If you want to protect all Model 2701RC rack cards installed in the current rack from being globally config-
ured, select protected(1) from the drop-down menu, then click the
Submit button. For more information about
the system configuration feature, refer to section “System Config” on page 259.