Section 9 Bus State Controller
Page 360 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
In the above conditions, a total of four conditions, that is, condition [1] or [2] (either one is
effective), condition [3] or [4] (either one is effective), a set of conditions [5] to [7] (these are
generated successively, and therefore the sum of them should be taken as one set of idle cycles),
and condition [8] are generated at the same time. The maximum number of idle cycles among
these four conditions become the number of idle cycles on the external bus. To ensure the
minimum idle cycles, be sure to make register settings for condition [1] or [2].
CKIO
CSn
Previous access
External bus idle cycles
Idle cycle after access
Either one of them
is effective
[1]
DMAIW[2:0] setting in CMNCR
[2]
IWW[2:0] setting in CSnBCR
IWRWD[2:0] setting in CSnBCR
IWRWS[2:0] setting in CSnBCR
IWRRD[2:0] setting in CSnBCR
IWRRS[2:0] setting in CSnBCR
[3]
WTRP[1:0] setting in CSnWCR
TRWL[1:0] setting in CSnWCR
WTRC[1:0] setting in CSnWCR
[4]
WM setting in CSnWCR
[6]
Internal bus idle cycles, etc.
[8]
Idle cycles
between
different
memory types
[5]
Read
data
transfer
[7]
Write
data
wait
Idle cycle before access
Next access
Condition [1] or [2]
A total of four conditions (condition [1] or [2], condition [3] or [4], a set of conditions [5] to [7],
and condition [8]) generate idle cycle at the same time. Accordingly, the maximum number of
cycles among these four conditions become the number of idle cycles.
Note:
Condition [8]
Condition [3] or [4]
Set of conditions
[5] to [7]
Either one of them
is effective
Figure 9.45 Idle Cycle Conditions