6. Axis Specifications Parameters
6.1 Axis Specifications Parameters
70
# Items Details
Setting range (unit)
2007 G1tL G1 time
constant
(linear)
Set up a linear control time constant for cutting
acceleration and deceleration.
The time constant is validated when LC (cutting feed
with linear acceleration and deceleration) or F
(acceleration and deceleration by software) is selected
in acceleration or deceleration mode "#2003 smgst."
G1tL
G1tL
Time
Speed
1 to 4000 (ms)
2008 G1t1 G1 time
constant
(primary
delay)
Second-step
time
constant for
acceleration
and
deceleration
by software
Set up the primary delay time constant for cutting
acceleration and deceleration.
The time constant is validated when C1 (cutting feed
with the primary delay) or C3 (cutting feed with
exponential acceleration and linear deceleration) is
selected in acceleration or deceleration mode "#2003
smgst."
When acceleration or deceleration by software is
selected, the second stage time constant is used.
G1t1
2 G1t1
G1t1
G1t1
G1tL G1tL
G1t1
G1t1
G1t1
G1t1
<Cutting feed with exponential
acceleration and linear deceleration>
Time
Speed
<Cutting feed with primary delay>
Time
Speed
Time
Speed
<Acceleration/deceleration by software>
1 to 5000 (ms)
2009 G1t2 Not used.