Mitsubishi Electronics C64 Crib Toy User Manual


 
16. Auxiliary Axis Parameters
307
No. Name Details Setting range
Default
value
190 stpos2 Station 2
coordinate
value
191 stpos3 Station 3
coordinate
value
192 stpos4 Station 4
coordinate
value
193 stpos5 Station 5
coordinate
value
194 stpos6 Station 6
coordinate
value
195 stpos7 Station 7
coordinate
value
196 stpos8 Station 8
coordinate
value
197 stpos9 Station 9
coordinate
value
Set the coordinate value of each station when
non-uniform assignment is selected.
The station 1 coordinate value is fixed at 0.000
(machine coordinate zero point).
–99999.999 to
99999.999
(° or mm)
0.000
200 PSWcheck PSW
detection
method
This is a HEX setting parameter. Set bits without a description to their default
values.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
Default
value
0000000000 0 0 0 000
bit
Position
switch
Meaning when "0" is set Meaning when "1" is set
0
PSW1
1 PSW2
2 PSW3
3 PSW4
4 PSW5
5 PSW6
6 PSW7
7 PSW8
The position switch output
is judged by the machine
position of the command
system.
The position switch output
is judged by the machine
FB position (actual
position).
8
9
A
B
C
D
E
F