5. Base Specifications Parameters
33
# Items Details
Setting range (unit)
1145 I_abs Manual ABS
parameter
Specify how to handle the absolute position data during
automatic handle interrupt.
0: Absolute position data is renewed if manual ABS
switch is on. Data is not renewed if switch is off.
1: Follows the intabs state when "#1061 intabs" is
valid.
0/1
1146 Sclamp Spindle
rotation
clamp
function
Specify how to handle the spindle rotation clamp
function with the G92S command.
0: G92S command is handled as a clamp command
only in the G96 state (during constant surface
speed control). G92S will be handled as normal S
command in G97 state (constant surface speed
OFF).
1: The S command in the same block as G92 is
constantly handled as a clamp command.
0/1
1147 smin_V Minimum
spindle
rotation
speed clamp
type
Specify the type of spindle min. rotation speed clamp
value.
0: Rotation speed setting
1: Output voltage coefficient setting
Set the "#3023 smini" parameter according to this type
setting.
0: Rotation speed
setting
1: Output voltage
coefficient
setting
1148 I_G611 Initial high
precision
Specify the default mode after power-on or resetting.
0: G64 (cutting mode)
1: G61.1 (high precision control mode)
0/1
1149 cireft Arc
decelera-
tion speed
change
Specify whether to enable deceleration at the arc
entrance or exit.
0: Disable
1: Enable
0/1
1150 F1dc0 G00 feed
forward filter
This parameter is used to filter acceleration changes at
the start of rapid acceleration/deceleration. Specify
the filters in bit units.
7 6 5 4 3 2 1 0
G00 feed forward filter
Feed forward filter
G00 and G01 independent
0: Common 1: Independent
bit1: 7.1 (ms)
bit2: 14.2 (ms)
bit3: 28.4 (ms)
bit4: 56.8 (ms)
If bit 1 to bit 4 are all
0 or two or more
bits of bit 1 to bit 4
are 1, 3.5 ms is set
up.
1151 rstint Reset initial Specify whether to initialize various modals by
resetting.
0: Does not initialize.
1: Initializes.
0/1