5. Base Specifications Parameters
29
# Items Details
Setting range (unit)
1114 mcrint Macro
argument
initialization
Select whether to clear statements other than
specified arguments by macro call. Also, select
whether to clear local variables by power-on and
resetting.
0: Delete non-specified arguments by macro call.
1: Retain non-specified arguments by macro call.
2: Retain non-specified arguments by macro call
and clear local variables by power-on and
resetting.
0/1/2
1115 thwait Waiting for
thread cutting
Set the queue number during screw thread cutting
when the chamfering is not valid.
0 to 99 (Approx. 4
ms.)
Standard set value:
4
1116
G30SLM
Invalidate
soft limit
(manual
operation)
Enable this function when disabling the soft limit check
function from the second to the fourth reference point
return by manual operation.
0: Enable soft limit
function.
1: Disable soft
limit function.
1117 H_sens Handle
response
switch
Switch the handle response mode when feeding the
handle.
0: Standard handle response
1: High-speed handle response
0/1
1118 mirr_A
(For L
system
only)
Select how to
set up the
length of
tools on
facing turret
(double-turret
mirror image)
Select one of the following two methods.
0: Set up the current length of tools on facing turret.
1: Set up a value, assuming that the tools on facing
turret is in the same direction as that of those on
the base turret.
0/1
1119 Tmiron
(For L
system
only)
Select the
double-turret
mirror image
with T
command
Select whether to validate the double-turret mirror
image with the T command.
0: Invalid
1: Valid
1120
(PR)
TofVal Change
macro
variable
Specify whether to change the macro variable (tool
offset) numbers for shape compensation and wear
compensation.
0: Do not change. (Conventional specifications)
1: Change the shape and wear compensation
variable numbers each for X, Z, and R.
0/1