5. Base Specifications Parameters
17
# Items Details
Setting range (unit)
1025 l_plane Initial plane
selection
Specify the plane to be selected when the power is
turned on or reset.
When 0 is specified, 1 is assumed (X-Y plane).
1
: X-Y plane (G17
command state)
2: Z-X plane (G18
command state)
3: Y-Z plane (G19
command state)
1026
1027
1028
base_l
base_J
base_K
Base axis I
Base axis J
Base axis K
Specify the basic axis address that composes the
plane.
Specify the axis address set in “#1013 axname”.
Set the axis name even when there is no need to
configure a plane, such as the case of 2-axis
specifications.
Normally‚ when X‚ Y and Z are specified respectively
for base_l‚_J‚_K‚ the following relation will be
established:
G17: X-Y
G18: Z-X
G19: Y-Z
Specify the desired address to set an axis address
other than the above.
Control axis
addresses such as
X, Y, and Z
1029 aux_I Flat axis I If there is an axis parallel to "#1026 base_l"‚ specify
that axis address.
Control axis
addresses such as
X, Y, and Z
1030 aux_J Flat axis J If there is an axis parallel to "#1027 base_J"‚ specify
that axis address.
Control axis
addresses such as
X, Y, and Z
1031 aux_K Flat axis K If there is an axis parallel to "#1028 base_K"‚ specify
that axis address.
Control axis
addresses such as
X, Y, and Z