Mitsubishi Electronics C64 Crib Toy User Manual


 
12. Position Switch
12.2 Canceling the Position Switch
286
Rotary axis
Setting of dog1 and dog2 Operation Description
dog1 < dog2
A signal is output
between dog1 and
dog2.
A signal is also output
when dog1 is negative.
dog1 > dog2
A signal is output
between dog2 and
dog1.
dog1 dog2 360
A signal is kept output
when the difference
between dog1 and dog2
exceeds 360 degrees.
12.2 Canceling the Position Switch
To cancel the position switch‚ enter the number (#751) of the position switch to be canceled in # ( )
of the setting area‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis
name for the specified position switch‚ thus invalidating the position switch.
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch
again‚ therefore‚ it is enough to specify the axis name only.