16. Auxiliary Axis Parameters
297
No. Name Details Setting range
Default
value
104
(PR)
tleng Linear axis
stroke
length
Set the movement stroke length for linear axes.
This is meaningless when setting non-uniform
assignments or commanding random positions.
0.001 to
99999.999
(mm)
100.000
110 ZRNspeed Reference
point return
speed
Set the clamp value of the feedrate when a
reference point return is carried out. The feedrate
becomes the manual operation speed of the
parameter group selected at that time, but it is
clamped by this parameter setting value.
1 to 100000
(°/min or
mm/min)
1000
111 ZRNcreep Reference
point return
creep speed
Set the approach speed to the reference point after
dog detection during a reference point return.
1 to 65535
(°/min or
mm/min)
200
112 grid mask Grid mask Set the amount that the dog is artificially extended.
Set 1/2 the grid spacing as a standard.
0 to 65536
(1/1000° or µm)
0
113
(PR)
grspc Grid
spacing
Divide the grid spacing that is the conventional
motor rotation movement amount into 2, 4, 8, or 16
divisions.
0 to 4
(1/2
n
division)
0
114 ZRNshift Reference
point shift
amount
Set the shift amount in a dog-type reference point
return from the electric zero point determined on
the grid to the reference point.
0 to 65536
(1/1000° or µm)
0
115 ST. ofset Station
offset
Set the distance (offset) from the reference point to
station 1.
–99999.999 to
99999.999
(° or mm)
0.000
116
(PR)
ABS base Absolute
position
zero point
When movement of the machine coordinate zero
point from the origin point is required during
absolute position initializing, set that movement
amount.
–99999.999 to
99999.999
(° or mm)
0.000
117 Limit (+) Soft limit (+) Commands in the plus direction that exceed this
setting value are not possible. If the machine is in a
position exceeding the setting value, commands in
the minus direction are possible.
The soft limit function will not operate if Limit (+)
and Limit (–) are set to the same value.
–99999.999 to
99999.999
(mm)
1.000
118 Limit (–) Soft limit (–) Commands in the minus direction that exceed this
value are not possible. If the machine is in a
position exceeding the setting value, commands in
the plus direction are possible.
–99999.999 to
99999.999
(mm)